5.3Regulation for LPG

Instructions for the installer

5.3Regulation for LPG

Check that the connection has been made as described in the “Gas connection” section.

Undo the screw “D” and push the air regulator “C” fully down. Use a spanner to remove the nozzles “B” and fit those of suitable type following the instructions given in the tables for bottled gas G30/G31 – 28/37 mbar. The nozzle must not be tightened to a torque of over 3 Nm. Regulate the air flow by moving the Venturi pipe “C”, until the gap “A” is as shown in the table in point “5.5 Regulation of primary air” and fix it with the screw “D”. After making the adjustments, restore the seals with sealing wax or an equivalent material.

Burner

Rated

heatingLPG – G30/G31 28/37 mbar capacity

Nozzle

 

By-pass

 

By-pass

 

Reduced

 

 

 

 

Diameter

 

1/100

 

1/100

 

 

Flowrate

 

Flowrate

 

 

 

flowrate

 

 

1/100

 

mm

 

mm

 

 

g/h G30

 

g/h G31

 

 

 

(W)

 

 

mm

 

[V(1)]

 

[NV(1)]

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

1.05

48

 

30

 

30

 

450

 

76

 

75

 

 

 

 

 

 

 

 

Semi-rapid

1.8

62

 

32

 

32

 

500

 

131

 

129

 

 

 

 

 

 

 

 

Rapid

2.55

76

 

42

 

42

 

750

 

185

 

182

 

 

 

 

 

 

 

 

Rapid large

3.1

85

 

45

 

45

 

850

 

225

 

222

 

 

 

 

 

 

 

 

Fish pan

2.9

82

 

50

 

50

 

950

 

211

 

207

 

 

 

 

 

 

 

 

Ultra rapid

4.0

95

 

63

 

65

 

1600

 

291

 

286

(1)V = Valved; NV = Nonvalved