Smeg AP64S3 Regulation for natural gas, Natural gas - G20 20 mbar, Instructions for the installer

Models: AP64S3

1 20
Download 20 pages 62.98 Kb
Page 11
Image 11
5.4Regulation for natural gas

Instructions for the installer

5.4Regulation for natural gas

The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph “5.3 Regulation for LPG”, but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph “5.5 Regulation of primary air”. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

 

 

Rated

 

Natural gas – G20 20 mbar

Burner

 

heating

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

Reduced flowrate

 

 

 

 

1/100 mm

 

(W)

 

 

 

 

 

 

Auxiliary

 

1.05

 

73

 

400

 

 

 

 

Semirapid

 

1.8

 

93

 

450

 

 

 

 

Rapid

 

2.55

 

115

 

750

 

 

 

 

Rapid large

 

3.1

 

128

 

750

 

 

 

 

Fish pan

 

2.9

 

123

 

950

 

 

 

 

Ultra rapid

 

4.0

 

142

 

1400

34

Page 11
Image 11
Smeg AP64S3 manual Regulation for natural gas, Natural gas - G20 20 mbar, Instructions for the installer