Smeg C9GMXA manual Regulation of the hob burner minimum level for natural gas, Final Operations

Models: C9GMXA

1 22
Download 22 pages 57.7 Kb
Page 10
Image 10
4.FINAL OPERATIONS

Instructions for the installer

4.FINAL OPERATIONS

After changing the nozzles, put the pan stands, the burner caps and flame diffuser rings back in place.

After adjusting for use of a gas other than the gas used for testing the appliance, replace the gas setting label on the appliance with the label for the new gas. The label is supplied in the bag with the nozzles.

4.1 Regulation of the hob burner minimum level for natural gas

Light the burner and turn it to the minimum position 4.1 Regulation of the hob burner minimum level for natural gas. Extract the gas tap knob and turn the adjustment screw at the side of the tap rod until the correct minimum flame is achieved.

Refit the knob and verify that the burner flame is stable (turning the knob rapidly from the maximum to the minimum position the flame must not go out). Repeat the operation on all the gas taps.

For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and to activate the safety device.

4.2 Regulation of the hob burner minimum level for ULPG

In order to adjust the minimum with ULPG, the screw at the side of the tap rod must be turned clockwise all the way. The bypass diameters for each individual burner are shown in paragraph "3.2 Burner and nozzle characteristics table". Once the regulation has been completed, restore the seal on the by- passes using paint or similar materials.

4.3 Mounting the rear top skirtboard

Loosen nuts B.

Position the skirt above the top, taking care to align pins C with holes D.

• Secure the skirt to the top by tightening screws A.

12

Page 10
Image 10
Smeg C9GMXA Regulation of the hob burner minimum level for natural gas, Mounting the rear top skirtboard, Final Operations