Smeg CC92MFX6 manual Final Operations, Regulation of the hob burner minimum level for natural gas

Models: CC92MFX6 CC92MFX5

1 20
Download 20 pages 62.38 Kb
Page 19
Image 19
15.FINAL OPERATIONS

Instructions for the installer

15.FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.

Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the appliance with the one corresponding to the new gas. This label is in the packet together with the nozzles.

15.1 Regulation of the hob burner minimum level for natural gas

Light the burner and turn it to the minimum position 15.1 Regulation of the hob burner minimum level for natural gas.

Remove the knob and turn the regulation screw inside or next to the gas tap pin (depending on the model) until you get a suitable minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and to activate the safety device.

15.2 Regulation of the hob burner minimum level for LPG

In order to adjust the minimum with LPG, the screw at the side of the tap rod must be turned clockwise all the way.

The bypass diameters for each individual burner are shown in paragraph “14.2 Burner and nozzle characteristics table". Once the regulation has been completed, restore the seal on the by-passes using paint or similar materials.

15.3 Mounting the rear top skirtboard (where applicable)

Loosen nuts B.

Position the skirt above the top, taking care to align pins C with holes D.

Secure the skirt to the top by tightening screws A.

15.4 Wall fixing

Stretch out the chain attached to the cooker horizontally so that the other end touches the wall.

Mark the wall in the position where the hole is to be drilled.

Drill the hole, insert a wall plug and attach the chain.

Move the cooker up against the wall.