Smeg CC92MFX6, CC92MFX5 Adaptation To Different Types Of Gas, Replacement of nozzles on the hob

Models: CC92MFX6 CC92MFX5

1 20
Download 20 pages 62.38 Kb
Page 17
Image 17
14.ADAPTATION TO DIFFERENT TYPES OF GAS

Instructions for the installer

14.ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, disconnect the appliance from the mains.

The cooker hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of operation with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below.

14.1 Replacement of nozzles on the hob

1Extract the grids and remove all the caps and flame-spreader crowns;

2Unscrew the burner nozzles with a 7 mm socket wrench;

3Replace the nozzles according to the type of gas to be used and the description in paragraph "14.2 Burner and nozzle characteristics table ";

4Replace the burners in the correct position.