York H*DA012 specifications Cooling Capacity, 1 & 3 PHASE HDA, WITH N1AH AIR HANDLER & G2FD COILS

Models: H*DA012

1 8
Download 8 pages 13.14 Kb
Page 4
Image 4

036-21105-004 Rev. A (0902)

COOLING CAPACITY

UNIT MODEL

 

AIR HANDLER

 

COIL MODEL

 

 

 

COOLING

 

 

MODEL

ELECTRIC HEAT KW

W

 

RATED

NET MBH

KW

SEER

 

 

 

CFM

TOTAL

 

SENS.

(EER)

 

 

 

 

 

 

 

 

1 & 3 PHASE HDA

WITH N1AH AIR HANDLER & G2FD COILS

 

 

 

 

 

 

 

 

H3DA018S78

N1AHB12

2,5,7.5,10

17

G2FD024S17

 

650

20.4

 

14.9

2.23

9.60

H3DA024S78

N1AHB12

2,5,7.5,10

17

G2FD024S17

 

800

23.5

 

17.1

3.07

8.90

N1AHB12

G2FD030S17

 

800

24.0

 

17.5

2.79

9.00

 

 

 

 

 

H3DA0308S78

N1AHB12

5,7.5,10,15,18

17

G2FD030S17

 

1025

30.0

 

21.9

3.32

9.70

-

17

G2FD036S17

 

1025

30.2

 

22.0

3.35

9.70

 

 

 

 

H3DA036S50

N1AHB12

5,7.5,10,15,18

17

G2FD036S17

 

1200

34.2

 

24.9

4.05

9.00

21

G2FD046S17

 

1200

-

 

-

-

-

 

 

 

 

 

 

N1AHC16

5,7.5,10,15,20

21

G2FD048S21

 

1550

46.2

 

34.7

5.06

9.90

H3DA048S50

N1AHD20

7.5,10,15,20,25,30

24

G2FD048S24

 

1550

46.2

 

34.7

5.06

9.90

 

N1AHD20

7.5,10,15,20,25,30

24

G2FD060S24

 

1550

47.8

 

35.9

5.16

9.90

H3DA060S50

N1AHD20

7.5,10,15,20,25,30

24

G2FD060S24

 

1800

60.0

 

43.9

6.45

9.40

1 & 3 PHASE HDA

WITH F2RP SINGLE PIECE AIR HANDLERS

 

 

 

 

 

 

 

 

H3DA018S78

F2RP024

2,5,7.5,10

18

-

 

650

16.9

 

12.5

2.0

-

 

 

 

 

 

 

 

 

 

 

 

 

H3DA024S78

F2RP024

2,5,7.5,10

18

-

 

850

21.0

 

15.5

2.5

-

H3DA030S78

F2RP036

5,7.5,10,15,19

21.5

-

 

1090

28.0

 

20.8

3.2

-

H3DA036S50

F2RP036

5,7.5,10,15,19

21.5

-

 

1090

35.3

 

23.8

4.2

8.5

H3DA048S50

F2RP048

10,15,20,25

24

-

 

1490

42.9

 

31.7

5.3

8.2

H3DA060S50

F2RP060

10,15,20,25

24

-

 

1735

54.1

 

24.5

6.4

8.4

3 PHASE HDA WITH

COMMERCIAL BELT DRIVE K*EU EVAPORATOR BLOWER UNIT

 

 

 

 

 

 

H3DA060S50

K2EU060

10,16,25

36

-

 

2000

55.5

 

39.5

6.30

10.00

H3DA076S50

K5EU090

10,16,26,36

52

-

 

2550

74.6

 

53.7

7.61

9.80

MBH based on 80°F entering air temperature, 50% RH, and rated air flow.

KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided

by the total electric power input inwatt-hours during the same period. (EER) = Energy Efficiency Ratio-steady state total BTUH/electric power input.

4

Unitary Products Group

Page 4
Image 4
York H*DA012 Cooling Capacity, 1 & 3 PHASE HDA, WITH N1AH AIR HANDLER & G2FD COILS, WITH F2RP SINGLE PIECE AIR HANDLERS