Instructions for the installer

For operation on 380-415V 3N~: use an H05V2V2-F type five-core cable (5 x 4 mm2).

For operation on 380-415V 2N~: use an H05V2V2-F type four-core cable (4 x 6 mm2).

The earth wire (yellow-green) must be at least 20 mm longer than the other wires at the end for connection to the appliance.

WARNING: The values indicated above refer to the cross-section of the internal conductor.

THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR DAMAGE TO PERSONS OR THINGS CAUSED BY NON-OBSERVANCE OF THE ABOVE PRESCRIPTIONS.

16.2 Positioning and levelling the appliance (depending on model)

After making the electrical connections, level the appliance on the ground by means of its four adjustable feet. For good cooking results, the appliance must be properly levelled. Depending on the model you have purchased, the foot height adjustment range may vary from 70 to 95 mm and from 110 to 160 mm. These heights refer to the distance between the highest point of the foot (fixed part) and the lowest point (movable part which rests on the floor).