Instructions for the installer
6 FINAL OPERATIONS
Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph “5.1 Removing the control panel / 5.2 Removing the hob”.
6.1Adjustment of minimum for natural gas
Light the burner and take it to the minimum . Remove the gas tap knob and turn the adjustment screw at the side of the tap shaft until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.
16