Instructions for the installer

5.4Adjustment for natural gas

The hob has been adjusted for natural gas at a pressure of 1.0kPa. To allow the unit to work back with this type of gas, after it has been adjusted for ULPG, perform the same operations described in paragraph “5.3 Adjustment for ULPG”, but refer to the following table for the proper injectors.

 

 

 

NG – 1.0 kPa

 

 

 

 

 

 

 

 

 

Burner

 

Nominal gas

 

Injector

 

 

Consumption

 

 

(mm)

 

 

 

 

 

 

 

 

(MJ/h)

 

 

 

 

 

 

 

 

 

Auxiliary

 

4.8

 

 

0.98

 

 

 

 

 

Semi-rapid

 

5.9

 

 

1.10

 

 

 

 

 

Rapid

 

8.6

 

 

1.25

 

 

 

 

 

Rapid large

 

11.4

 

 

1.50

 

 

 

 

 

Fish pan

 

11.4

 

 

1.50

 

 

 

 

 

Wok

 

15

 

 

1.70

15