5.3 Adjustment for natural gas

Instructions for the installer

5.3 Adjustment for natural gas

The hob has been adjusted for natural gas at a pressure of 1.0kPa.

To allow the unit to work back with this type of gas, after it has been adjusted for LPG, perform the same operations described in paragraph “5.2 Adjustment for LPG”, but refer to the following table for the proper injectors.

 

 

 

 

 

 

NG – 1.0 kPa

 

 

 

 

Burner (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal gas

 

 

Injector

 

 

 

 

 

 

 

 

consumption

 

 

(mm)

 

 

 

 

 

 

 

 

(MJ/h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (1)

 

 

4.8

 

 

0.98

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi rapid (2)

 

 

6.0

 

 

1.10

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (6)

 

 

11.5

 

 

1.50

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (3)

 

 

12.2

 

 

1.55

 

 

 

 

 

 

 

 

 

 

 

 

 

Wok (4)

 

 

15.0

 

 

1.70

 

 

 

Wok (dual control) (5)

 

 

 

 

15.0

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outer

 

 

11.5

 

 

1.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inner

 

 

3.5

 

 

0.85

 

 

(*) For burner reference numbers, see page 15.

 

 

 

 

 

 

6. FINAL OPERATIONS

Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph “5.1 Removing the hob”.

6.1 Adjustment of minimum for natural gas

Light the burner and take it to the minimum 6. FINAL OPERATIONS. Remove the gas tap knob and turn the adjustment screw inside or at the side of the tap shaft (depending on the model) until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.