3.2 Adjustment for LPG

Instructions for the installer

3.2 Adjustment for LPG

Loosen screw A and push air regulator B to the bottom. With a 7 mm wrench, remove nozzle C and replace it with the proper one (follow the instructions on the reference tables for the type of gas to be used). The torque wrench setting of the nozzle must not exceed 3 Nm. Adjust the air by sliding regulator B until reaching distance “X” shown in the table in paragraph “3.4 Regulation of primary air”. Lock regulator B by tightening screw A.

 

 

 

 

Model CSA19

 

 

 

Models CSA196 / CSA20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

 

 

LPG – 2.75 kPa

 

 

 

 

LPG – 2.75 kPa

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal gas

 

 

Turn-down gas

 

Injector

 

Nominal gas

 

Turn-down gas

 

 

Injector

 

 

 

 

consumption

 

 

consumption

 

(mm)

 

consumption

 

consumption

 

 

(mm)

 

 

 

 

(MJ/h)

 

 

(MJ/h)

 

 

 

(MJ/h)

 

(MJ/h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

4.80

 

1.5

 

0.60

 

5.30

 

1.5

 

 

0.62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi rapid

 

5.80

 

1.5

 

0.67

 

6.60

 

1.5

 

 

0.70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid

 

9.30

 

3.2

 

0.85

 

9.00

 

3.2

 

 

0.82

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wok

 

13.00

 

5.4

 

1.00

 

15.00

 

5.4

 

 

1.05

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fish burner (*)

 

9.20

 

3.2

 

0.85

 

6.60

 

2.9

 

 

0.70

 

(*)Models CSA19 / CSA196

3.3Adjustment for natural gas

The hob has been tested for natural gas at a pressure of 1.0kPa. To allow the unit to work with this type of gas, perform the same operations described in paragraph “3.2 Adjustment for LPG”, but choose the nozzles and adjust the primary air for natural gas, as shown in the following table and in paragraph “3.4 Regulation of primary air”.

 

 

Model CSA19

 

Models CSA196 / CSA20

 

Burner

 

NG – 1.00 kPa

 

 

NG – 1.00 kPa

 

 

 

 

 

 

 

 

Nominal gas

Turn-down gas

Injector

Nominal gas

Turn-down gas

Injector

 

consumption

consumption

(mm)

consumption

consumption

(mm)

 

(MJ/h)

(MJ/h)

 

(MJ/h)

(MJ/h)

 

Auxiliary

5.30

1.4

1.04

5.30

1.4

1.00

Semi rapid

6.60

1.4

1.15

6.60

1.4

1.15

Rapid

9.00

2.4

1.35

9.00

2.4

1.35

Wok

12.50

4.3

1.65

15.00

4.3

1.75

Fish burner (*)

10.20

3.2

1.45

6.60

2.9

1.15

(*) Models CSA19 / CSA196

 

 

 

 

 