Smeg CSA19ID-6 manual Adaptation To Different Types Of Gas, Raising of the hob

Models: CSA19ID-6

1 32
Download 32 pages 19.86 Kb
Page 9
Image 9
3. ADAPTATION TO DIFFERENT TYPES OF GAS

Instructions for the installer

3. ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, detach the appliance from the electrical socket.

The hob of the cooker is adjusted for use with natural gas at a pressure of 1.0kPa. If used with other types of gas, you have to replace the nozzles and regulate the primary air to the burners. Then adjust the minimum flame on the gas taps. For nozzle replacement and burner adjustment you must raise the hob as described in the following paragraph.

3.1 Raising of the hob

Remove the grids, first the middle one then the ones at the sides; remove all the burner caps, the flame cap crowns and the burners.

1.Remove the programmer buttons;

2.Remove the knobs;

3.Unscrew the front panel fixing screws and remove it after disconnecting the thermostat tell-tale light faston;

4.Loosen the screws of the hinge on the back of the cooker;

5.Raise the surface from the front end;

6.Place the surface support brackets in the front groove of the side;

7.Proceed to replacement of the burner nozzles in accordance with the appropriate gas table;

8.Adjust the primary air as described in paragraph “3.2 Adjustment for LPG”;

9.After adjustment, fully tighten the fixing screws.

11

Page 9
Image 9
Smeg CSA19ID-6 manual Adaptation To Different Types Of Gas, Raising of the hob, Instructions for the installer