95
GB
Oven installation

Connection

Electrical connections must be made as per the connection plate fixed to the back of the
appliance, by an electrical fitter, who must ensure that the appliance has been connected
up in accordance with fitting instructions and local regulations.
Where the appliance is not connected to the mains electricity supply by a plug, an omni polar
cutout device (with a contacts gap of at least 3 mm) must be fitted on the supply side of
the connection to meet safety requirements.
NOTE: When power is connected, the electronics of the oven are initialised; this neutralizes
the lighting for a few seconds.
If the oven is connected to the power supply by a plug, this must remain accessible once
the oven has been installed.
We cannot accept any liability in the event of an accident resulting from non-existent or
faulty earthing.
Operating voltage.......................................................................220-240 V ~ 50 Hz
Total wattage used in cooking...................................................................3.561 kW
Nominal power of grill..................................................................................1,5 kW
Power output in microwaves........................................................................1000 W
Energy consumption
-while heating to 175°C...........................................................................0,29 kWh
-to maintain 175°C for 1 hour...................................................................0,78 kWh
TOTAL....................................................................................................1,07 kWh
Inside dimensions of oven
Width.........................................................................................................42 cm
Height.........................................................................................................21 cm
Depth..........................................................................................................37 cm
Effective volume......................................................................................32 litres
min.
network voltage connection diameter of fuse
cable
230V~ 50Hz 1 Ph + N 1,5 mm216 A
Certain internal components can cause electric shocks, even after the power has been
turned off. For any repairs requiring the removal of a protective cover providing
protection against exposure to microwaves, only qualified staff can work on the
appliance without the risk of danger. If the power cable is damaged, it must be repla-
ced by the after-sales service department or similarly qualified
personnel in order to avoid all risks of danger.
99634252_ML_A.qxd 19/11/04 15:06 Page 95