Smeg FS61XPZ5 manual Adaptation To Different Types Of Gas, Replacement of nozzles on the hob

Models: FS61XPZ5

1 30
Download 30 pages 13.37 Kb
Page 8
Image 8
3. ADAPTATION TO DIFFERENT TYPES OF GAS

Instructions for the installer

3. ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, disconnect the appliance from the mains.

The hob of the cooker is adjusted for use with either natural gas at a pressure of 1.0kPa. If used with other types of gas, you have to replace the nozzles, then adjust the minimum flame on the gas taps. For nozzle replacement and burner adjustment operate as described in the following paragraph.

3.1Replacement of nozzles on the hob

This operation requires no primary air regulation.

1.Extract the grids and remove all the caps and flame-spreader crowns;

2.unscrew the burner nozzles with a 7 mm socket wrench;

3.replace the nozzles according to the type of gas to be used and the description in paragraph "3.2 Burner and nozzle characteristics table".

4.Replace the burners in the correct position.

10

Page 8
Image 8
Smeg FS61XPZ5 Adaptation To Different Types Of Gas, Replacement of nozzles on the hob, Instructions for the installer