4. FINAL OPERATIONS

Instructions for the installer

4. FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.

4.1Adjustment of the hob burner minimum level for natural gas

Light the burner and take it to the minimum 4.1Adjustment of the hob burner minimum level for natural gas. Remove the gas tap knob and turn the adjustment screw inside of the tap shaft (depending on the model) until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

4.2Adjustment of the hob burner minimum level for LPG

(propane)

To regulate the minimum for LPG (propane), completely tighten (clockwise) the screw inside or next to the gas tap pin (depending on the model).

4.3Arrangement of the burners on the hob

Burners

1 Auxiliary

2

Semi rapid

 

 

4 Wok

13

Page 11
Image 11
Smeg FS61XPZ5 Final Operations, Adjustment of the hob burner minimum level for natural gas, Instructions for the installer