5.5Regulation of primary air

Instructions for the installer

5.5Regulation of primary air

Referred to distance “X” in mm.

 

 

BURNER

 

 

G20

 

G30/G31

 

G110

 

 

 

 

 

 

 

 

 

20 mbar

 

28/37 mbar

 

8 mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (1)

 

 

1.5

 

1.0

 

0.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi-rapid (2)

 

 

1.5

 

1.5

 

0.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (3)

 

 

1.0

 

1.5

 

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ultra rapid (4)

 

 

2.0

 

2.5

 

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Double crown

 

internal (5)

 

3.0

 

6.0

 

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

external (5)

 

3.0

 

10.0

 

5.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fish pan (6)

 

 

2.0

 

2.5

 

1.0

 

 

 

To identify the burners on your hob, refer to the drawings

 

in point “6.3

Arrangement of burners on hob “

 

 

 

 

 

 

 

 

 

33

Page 12
Image 12