5.3 Regulation for natural gas

Instructions for the installer

5.3 Regulation for natural gas

The hob has been inspected for G25 (2L 3B/P) at a pressure of 2 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph “5.2 Regulation for LPG”, but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph "5.4 Regulation of primary air”. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

 

 

Rated

 

 

 

 

 

 

Burner

 

heating

 

Natural gas – G25 25 mbar

 

 

 

capacity

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

 

 

Reduced flowrate

 

 

 

 

 

1/100 mm

 

 

(W)

 

 

 

 

 

 

 

 

Auxiliary (1)

 

1.05

 

76

 

 

380

 

 

 

 

 

 

 

 

Semi-rapid (2)

 

1.65

 

98

 

 

380

 

 

 

 

 

 

 

Rapid (3)

 

2.7

 

123

 

 

650

 

 

 

 

 

 

 

Rapid (4)

 

3.1

 

130

 

 

750

 

 

 

 

 

 

 

Ultra rapid (5)

 

3.9

 

150

 

 

1400

 

5.4Regulation of primary air

Referred to distance “X” in mm.

BURNER

 

G25

 

 

 

25 mbar

 

 

 

 

 

 

 

 

 

Auxiliary (1)

 

1.5

 

 

 

 

Semi-rapid (2)

 

1.0

 

 

 

 

Rapid (3)

 

1.0

 

 

 

 

Rapid (4)

 

1.5

 

 

 

 

Ultra rapid (5)

 

1.5

 

G30/G31

28/37 mbar

2.0

1.5

5.0

10.0

4.0

31