5.2 Regulation for LPG

Instructions for the installer

5.2 Regulation for LPG

Loosen screw A and push support B all the way. Use a double head wrench to remove nozzle C and assemble the suitable one, following the instructions indicated in the reference charts, with respect to the type of gas to use. The screwing torque of the nozzle should never exceed 3 Nm. Reposition support B so that nozzle C is covered perfectly.

Move the Venturi tube D to regulate the air flow until distance "X" is reached indicated in the chart in paragraph "5.4 Regulation of primary air” and then secure the tube by means of screw A. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

Burner

Rated

heating

capacity

(kW)

LPG – G30/G31 28/37 mbar

Auxiliary (1)

Semi-rapid (2)

Rapid (3)

Rapid (4)

Ultra rapid (5)

Nozzle

diameter

1/100 mm

1.0548

1.6562

2.5576

3.185

3.995

By-pass

Reduced

mmflowrate

1/100 (W)

30

33 (*)

380

30

33 (*)

380

37

40 (*)

650

43

45 (*)

750

 

65

1600

 

Flowrate

 

Flowrate

 

 

 

 

 

g/h G30

 

g/h G31

 

 

 

 

 

 

76

75

120

118

185

182

225

222

283

279

(*) By-pass value for valveless appliances.

30

Page 10
Image 10
Smeg GKC641-3 manual Regulation for LPG, Instructions for the installer, Burner, Rated heating capacity kW