MAINTENANCE

MAINTENANCE

Grease filters

CLEANING METAL SELF- SUPPORTING GREASE FILTERS

The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher.

Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.

Wash the filters, taking care not to bend them. Allow them to dry before refitting.

When refitting the filters, make sure that the handle is visible on the outside.

Activated charcoal filter (Recirculation version)

REPLACING THE ACTIVATED CHARCOAL FILTER

The filter is not washable and cannot be regenerated, and must be replaced approximately every 4 months of operation, or more frequently for particularly heavy usage.

Remove the metal grease filters.

Remove the saturated activated carbon filter by releasing the fixing hooks.

Fit the new filter by hooking it into its seating.

Refit the metal grease filters.

Lighting

LIGHT REPLACEMENT

40 W incandescent light.

Remove the metal grease filters.

Unscrew the bulbs and replace them with new ones having the same characteristics.

Replace the metal grease filters.