5.4Regulation of primary air

Instructions for the installer

5.4Regulation of primary air

Referred to distance “X” in mm.

BURNER

 

G20

 

G30/G31

 

 

20 mbar

 

28/37 mbar

 

 

 

 

 

Auxiliary

 

 

4

 

open

 

 

 

 

 

 

 

 

Semi rapid

 

 

3

 

2

 

 

 

 

 

 

 

 

Medium rapid

 

 

2

 

2.5

 

 

 

 

 

 

 

 

Large rapid

 

 

2

 

2.5

 

 

 

 

 

 

 

 

 

UR

 

A

 

2

 

14

 

 

 

 

 

 

 

 

 

 

 

 

B

 

2

 

14

 

To identify the burners on your hob, refer to the drawings in point “5.8 Arrangement of burners on hob “

If after air setting the flame appears as shown in the diagram:

ABC

the following adjustments must be made:

A:the flame is noisy and unstable and comes away from the burner; the primary air intake is open too far.

B:The flame is cloudy and dull or has yellow dots and wraps round the burner; the primary air intake is closed too far.

C:The flame is blue, clear and stable and neither comes away from or wraps round the burner; the air is set correctly.

5.5Reassembling the hob

Follow the instructions given in paragraph “5.1 Removing the hob ”, but in the reverse order.

When replacing the burner rings, remember that they have to be tightened completely by means of the wrench supplied, otherwise the flame interruption zones on the flame caps will not be aligned with the grid spokes.

When positioning the grids, make sure that the pins are aligned with their seats in the surface, then press them in with the palm of your hand until they lock in place.

5.6Regulation of minimum for natural gas

Replace the components on the burner and slide the knobs on the gas tap pins.

Light the burner and set it at minimum position .

 

Remove the knob and turn the regulation screw inside

**

or next to the gas tap pin (depending on the model)

 

until you get a suitable minimum flame.

 

Replace the knob and check flame stability by rapidly

*

turning the knob from maximum to minimum. The

 

flame should not go out.

 