Smeg PGA95F3, PGA95FSC3 manual Adaptation To Different Types Of Gas, Instructions for the installer

Models: PGA95SC3 PGA95FSC3 PGA95F3

1 20
Download 20 pages 32.06 Kb
Page 12
Image 12
4. ADAPTATION TO DIFFERENT TYPES OF GAS

Instructions for the installer

4. ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, detach the appliance from the electrical socket.

The hob of the cooker is adjusted for use with either natural gas at a pressure of 1.0 kPa. If used with other types of gas, you have to replace the nozzles, then adjust the minimum flame on the gas taps. For nozzle replacement and burner adjustment operate as described in the following paragraph.

4.1Replacement of nozzles on the hob

This operation requires no primary air regulation.

1.Extract the grids and remove all the caps and flame-spreader crowns;

2.unscrew the burner nozzles with a 7 mm socket wrench;

3.replace the nozzles according to the type of gas to be used and the description in paragraph “4.2 Burner and nozzle characteristics table”.

4.Replace the burners in the correct position.

14

Page 12
Image 12
Smeg PGA95F3 Adaptation To Different Types Of Gas, Instructions for the installer, 4.1Replacement of nozzles on the hob