Smeg PGA95FSC3 Instructions for the installer, 2.3Clearance above and around domestic appliances

Models: PGA95SC3 PGA95FSC3 PGA95F3

1 20
Download 20 pages 32.06 Kb
Page 7
Image 7
2.3Clearance above and around domestic appliances

Instructions for the installer

2.3Clearance above and around domestic appliances

Extract from AS5601

REQUIREMENTS

1Overhead clearances – (Measurement A)

Range hoods and exhaust fans shall be installed in accordance with

the manufacturer’s instructions. However, in no case shall the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600 mm or, for an overhead exhaust fan, 750 mm.

Any other downward facing combustible surface less than 600 mm above the highest part of the hob shall be protected for the full width and depth of the cooking surface area in accordance with Clause 5.12.1.2. However, in no case shall this clearance to any surface be less than 450 mm.

9

Page 7
Image 7
Smeg PGA95FSC3, PGA95F3 Instructions for the installer, 2.3Clearance above and around domestic appliances, Requirements