Instructions for the installer
3.2Burner and nozzle characteristics table
| Rated |
|
|
|
|
Burner | heating |
| LPG – G30/G31 30/37 mbar | ||
| capacity |
|
|
|
|
| (kW) |
|
|
|
|
|
|
|
|
|
|
|
|
| Nozzle |
|
| ||||
|
|
| diameter |
| mm |
| |||
|
|
| 1/100 mm |
| 1/100 |
| |||
|
|
|
|
|
|
|
|
|
|
| Auxiliary (1) | 1.05 | 50 |
| 27 (*) |
|
| 28 (**) |
|
|
|
|
|
|
|
| |||
| Semi rapid (2) | 1.8 | 65 |
| 33 (*) |
|
| 32 (**) |
|
|
|
|
|
|
|
| |||
| Rapid (3) | 2.3 | 75 |
| 43 (*) |
|
| 42 (**) |
|
|
|
|
|
|
|
|
| ||
| Ultra rapid (4) | 3.5 | 94 |
|
| 63 |
|
| Reduced |
| Flow rate |
|
| flow rate |
| g/h G30 |
|
| (W) |
|
|
|
|
|
|
| |
| 350 |
| 76 |
|
|
|
|
| |
| 450 |
| 130 |
|
|
|
|
| |
| 800 |
| 166 |
|
|
|
|
|
|
1.6253
Flow rate
g/h G31
75
128
164
250
*/**: diameters marked * and ** must be fitted respectively on valves marked * and **shown in point “4.1 Regulation of minimum for natural gas”.
|
| Rated |
|
|
|
| Burner | heating | Natural gas – G20 20 mbar |
| |
|
| capacity |
|
|
|
|
| (kW) |
|
|
|
|
|
|
|
|
|
|
|
| Nozzle diameter | Reduced flow rate |
|
|
|
| 1/100 mm | (W) |
|
|
|
|
|
|
|
| Auxiliary (1) | 1.05 | 72 | 350 |
|
|
|
|
|
|
|
| Semi rapid (2) | 1.8 | 97 | 450 |
|
|
|
|
|
|
|
| Rapid (3) | 2.3 | 103 | 800 |
|
|
|
|
|
|
|
| Ultra rapid (4) | 3.5 | 133 | 1500 |
|
|
|
|
|
|
|
|
| Rated |
|
|
|
| Burner | heating | Town gas – G110 8 mbar |
| |
|
| capacity |
|
|
|
|
| (kW) |
|
|
|
|
|
|
|
|
|
|
|
| Nozzle diameter | Reduced flow rate |
|
|
|
| 1/100 mm | (W) |
|
|
|
|
|
|
|
| Auxiliary (1) | 1.05 | 145 | 350 |
|
|
|
|
|
|
|
| Semi rapid (2) | 1.8 | 185 | 450 |
|
|
|
|
|
|
|
| Rapid (3) | 2.3 | 220 | 800 |
|
|
|
|
|
|
|
| Ultra rapid (4) | 3.3 | 290 | 1500 |
|
Values for town gas are based on category III 1a2H3+ appliances.
3.3Arrangement of burners on cooking hob
BURNERS
1 Auxiliary
2 Semi rapid
3 Rapid
4 Ultra rapid
30