Smeg PTSA727X manual Clearance above and around domestic appliances, Requirements

Models: PTSA727X

1 16
Download 16 pages 48.77 Kb
Page 6
Image 6
3.1 Clearance above and around domestic appliances

Instructions for the Installer

3.1 Clearance above and around domestic appliances

Extract from AS5601

REQUIREMENTS

1Overhead clearances – (Measurement A)

Range hoods and exhaust fans shall be installed in accordance with the

manufacturer’s instructions. However, in no case shall the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600 mm or, for an overhead exhaust fan, 750 mm.

Any other downward facing combustible surface less than 600 mm above the highest part of the hob shall be protected for the full width and depth of the cooking surface area in accordance with Clause 5.12.1.2. However, in no case shall this clearance to any surface be less than 450 mm.

2 Side clearances – (Measurements B & C)

Where B, measured from the periphery of the nearest burner to any vertical combustible surface, is less than 200 mm, the surface shall be protected in accordance with

Clause 5.12.1.2 to a height C of not less than 150 mm above the hob for the full

dimension (width or depth) of the cooking surface area. Where the cooking appliance is fitted with a ‘splashback’, protection of the rear wall is not required.

3 Additional requirements for Freestanding and Elevated Cooking Appliaces –

(Measurements D & E)

Where D, the distance from the periphery of the nearest burner to a horizontal combustible surface is less than 200 mm, then E shall be 10 mm or more, or the horizontal surface shall be above the trivet. See insets above.

8

Page 6
Image 6
Smeg PTSA727X manual Clearance above and around domestic appliances, Requirements, Instructions for the Installer