5.2Adjusting for bottled gas

Instructions for the Installer

5.2Adjusting for bottled gas

Undo the screw A and push the support B fully down. Remove the nozzle C with a spanner and fit the suitable one following the instructions in the tables referring to the type of gas to be used. The nozzle must not be tightened with a torque of more than 3 Nm. Return the support B to its original position, so that the nozzle C is perfectly covered. Regulate the air flow by moving the Venturi pipe D until the distance “X” stated in point "5.4 Adjusting the primary air flow” is obtained and secure it with the screw A. When the adjustments are complete, restore the seals with wax or an equivalent material.

 

Burner

 

 

ULPG – 2.75 kPa

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal gas

 

 

Injector

 

 

 

 

 

 

 

Consumption (MJ/h)

 

 

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

 

4.8

 

 

0.60

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi rapid

 

 

6.0

 

 

0.68

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (3)

 

 

12.6

 

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (6)

 

 

11.2

 

 

0.85

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (7)

 

 

11.2

 

 

0.85

 

 

 

 

 

 

 

 

 

 

 

 

 

WOK double

 

Internal

 

3.9

 

 

0.50

 

 

 

flame (8)

 

 

 

 

 

 

 

 

 

 

External

 

15.1

 

 

1.05

 

 

 

 

 

 

 

 

 

 

 

 

WOK double

 

Internal

 

3.9

 

 

0.50

 

 

 

flame (4)

 

 

 

 

 

 

 

 

 

 

External

 

14.4

 

 

0.98

 

 

 

 

 

 

 

 

 

 

 

 

WOK

 

15.1

 

 

1.05

 

 

5.3Adjusting for natural gas

The appliance is tested with natural gas at the pressure of 1.0 kPa. To return the appliance to the condition required to use this type of gas, proceed as described in point “5.2 Adjusting for bottled gas” but select the nozzles and adjust the primary air flow for natural gas, as indicated in the table below and in point “5.4 Adjusting the primary air flow”.

 

Burner

 

 

Natural gas – 1.0 kPa

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal gas

 

Injector

 

 

 

 

 

 

 

Consumption (MJ/h)

 

(mm)

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

 

4.5

 

0.98

 

 

 

 

 

 

 

 

 

 

 

Semi rapid

 

 

6.1

 

1.10

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (3)

 

 

12.6

 

1.60

 

 

 

 

 

 

 

 

 

 

 

 

Rapido (6)

 

 

11.9

 

1.55

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (7)

 

 

10.8

 

1.45

 

 

 

 

 

 

 

 

 

 

 

WOK double

 

Internal

 

3.6

 

0.85

 

 

 

flame (8)

 

 

 

 

 

 

 

 

External

 

15.1

 

1.70

 

 

 

 

 

 

 

 

 

 

WOK double

 

Internal

 

3.6

 

0.85

 

 

 

flame (4)

 

 

 

 

 

 

 

 

External

 

14

 

1.65

 

 

 

 

 

 

 

 

 

 

WOK

 

 

15.1

 

1.70

 

 

12