Elkay VRCHDTL8 manual REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER, Page

Models: VRCHDTL8

1 6
Download 6 pages 48.09 Kb
Page 2
Image 2
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER

98510C (Rev. B - 8/09)

5 3/4" 146mm

5/16" DIA. (10 HOLES) 8mm (10 AGUJEROUS)

8mm ( 10 TROUS)

6 1/2" 165mm

13/8"

35mm

13/8"

35mm

185/16"

465mm

53/4"

146mm

53/4"

146mm

1 3/8"

1 3/8"

35mm

35mm

53/4"

146mm

3"

77mm

189/16"

472mm

HANGER BRACKETS FIJADOR DE SUSPENSION SUPPORT DE SUSPENSION

C

L

D

39 1/16" 992mm

ORIFICE HEIGHT

Page 2

FIG. 2

E LEGEND/LEYENDA/LÉGENDE

361/8"

918mm

F

191/8"

486mm

1 9/16" 40mm

2 7/16" 63mm

5"

10"

127mm

254mm

B

FINISHED FLOOR

PISO ACABADO

PLANCHER FINI

C = 1-1/2 TRAP NOT FURNISHED E

A

C

L

F

 

25 1/8"

 

 

 

638mm

 

 

 

20 1/8" 511mm

3 1/2"

 

89mm

12 5/8"

4 1/2"

320mm

 

114mm

 

5"

18 3/4"

127mm

476mm

329/16"

827mm

ORIFICE

HEIGHT

27" * 686mm

311/2"

800mm

RIM

HEIGHT

81/8"

206mm

515/16"

150mm

C D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX

61/2"

166mm

VRCHDTL8*1A VRCHDTLD*1A

REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER

*ADA REQUIREMENT

*REQUISITO DE A.D.A.

*EXIGENCE ADA

LEGEND/LEYENDA/LÉGENDE

A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL

La UBICACION 3/8 O RECOMENDADA de ABASTECIMIENTO DE AGUA. D. El TUBO del COBRE de UNPLATED CONECTA TALONARIO CON APAGO (POR OTROS) 3 en. (76 Mm) el MAXIMO FUERA DE PARED

L’O.D de 3/8 d’EMPLACEMENT DE PROVISION D’EAU RECOMMANDE. LE TUBE DE CUIVRE DE UNPLATED CONNECTE STUB AVEC ETEINT (PAR LES AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU MUR

B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM WALL

UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1-1/2” DE DIÁMETRO. El TALONARIO 2 FUERA DE PARED

EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/2" DE SORTIE D’EAU. STUB 2 HORS DU MUR

C = 1-1/2 TRAP NOT FURNISHED

PURGADOR DE 1-1/2 NO PROPORCIONADO

SIPHON 1-1/2 NON FOURNI

D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX

CAJA RECESIVA DE ALAMBRES (3) DE SUMINISTRO ELÉCTRICO

BOÎTE ENCASTRÉE D’ALIMENTATION ÉLECTRIQUE (3) FILS

E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.

ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6" (152 mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6" (152 mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.

F = 5/16 BOLT HOLES FOR FASTENING UNIT TO WALL

AGUJEROS DE LAS TUERCAS DE 5/16 PARA SUJETAR LA UNIDAD A LA PARED

TROUS D’ÉCROUS 5/16 POUR FIXER L’APPAREIL AU MUR

Page 2
Image 2
Elkay REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER, Page, VRCHDTL8*1A VRCHDTLD*1A, 98510C Rev. B - 8/09