Smeg PVA750BE, PVA750NL manual Adapting to different types of gas, Instructions for the Installer

Models: PVA750D PVA750 PVA750NL PVA750BE

1 18
Download 18 pages 29.38 Kb
Page 8
Image 8
5.Adapting to different types of gas

Instructions for the Installer

5.Adapting to different types of gas

The operations described below must be carried out with the appliance not built-in and not connected to the gas or electricity supply.

The appliance is tested with G20 (2H) natural gas at the pressure of 20 mbar.

If it is to be used with other types of gas, the burner nozzles have to be changed and the primary air flow adjusted.

To replace the nozzles and adjust the burners, the hob skin has to be removed. Proceed as described below.

5.1 Removing the hob skin

Remove all the burner components in the numerical order shown below:

Pull off all the knobs.

Lift all the burner components off the hob.

1

Remove the cover plate of each burner by undoing the screws.

2

Remove the hob skin fixing screws, taking care only to remove the screws shown on the right.

3

After removing all the

components described above, lift off the hob skin.

4

28

Page 8
Image 8
Smeg PVA750BE, PVA750NL, PVA750D Adapting to different types of gas, Instructions for the Installer, Removing the hob skin