14. INSTALLATION

It is the law that all gas appliances are installed by authorised persons. Clearance around the cooker must comply with the requirements of AS5601.

14.1 Electrical connection

Check that the voltage and dimensioning of the supply line correspond to the characteristics shown on the plate fixed to the rear protective cover of the appliance.

This plate must never be removed.

The plug at the end of the power cable and the wall socket must be the same type (conforming to regulations in force). Check that the power line is adequately grounded. Do not use reducers, adapters or shunts.

On the power line, install an omnipolar cut-off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit.

The connection terminals are located at the rear of the

appliance. For electrical connections see following diagram. To access, remove the rear cover.

For operation on 380-415V3N~ : use an H05RR-F / H05RN-F / H05V2V2-F type five-core cable (5 x 1.5 mm2).

For operation on 380-415V2N~ : use an H05RR-F / H05RN-F / H05V2V2-F type five-core cable (cavo di 4 x 1.5 mm2).

For operation on 220-240V~ : use an H05RR-F /

H05RN-F / H05V2V2-F (cavo di 3 x 2.5 mm2).

The cable end to be connected to the appliance must be provided with an ground wire (yellow-green) at least 20 mm longer.

The manufacturer declines all responsibility for damage to persons or things caused by non- observance of the above prescriptions or by interference with any part of the appliance.