15.2 Burner and nozzle characteristics table

Instructions for the installer

15.2 Burner and nozzle characteristics table

Burner

 

 

 

ULPG (PROPANE) – 2.75 Kpa

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal gas

 

Turn-down gas

 

 

 

 

 

consumption

 

consumption

 

 

Injector (mm)

 

 

(MJ/h)

 

(MJ/h)

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

3.9

1.26

 

 

0.54

 

 

 

 

 

 

 

 

Semi rapid

6.3

1.62

 

 

0.68

 

 

 

 

 

 

 

 

Triple crown

12.8

5.4

 

 

100

 

 

 

 

 

 

Burner

 

 

 

NG – 1.0 Kpa

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal gas

 

Turn-down gas

 

 

 

 

 

consumption

 

consumption

 

 

Injector (mm)

 

 

(MJ/h)

 

(MJ/h)

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

3.9

1.26

 

 

0.90

 

 

 

 

 

 

 

 

Semi rapid

6.5

1.62

 

 

1.20

 

 

 

 

 

 

 

 

Triple crown

15

4.32

 

 

1.75

15.3Arrangement of the burners on the hob

15.3Arrangement of the burners on the hob BURNERS

1.Auxiliary

2.Semi rapid

4. Triple crown