Instructions for the installer

5.2Regulation for LPG

Loosen screw A and push support B all the way. Use a double head wrench to remove nozzle C and assemble the suitable one, following the instructions indicated in the reference charts, with respect to the type of gas to use. The screwing torque of the nozzle should never exceed 3 Nm. Reposition support B so that nozzle C is covered perfectly.

Move the Venturi tube D to regulate the air flow until distance “X” is reached indicated in the chart in paragraph “5.4 Regulation of primary air” and then secure the tube by means of screw A. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

Rated

Burnerheating capacity

LPG – G30/G31 28/37 mbar

Auxiliary (1)

1.05

Semirapid (2)

1.65

Rapid (3)

2.55

Rapid large (4)

3.1

Fish pan (7)

2

Ultra rapid (5)

3.3

Double Internal

1.15

crown

External

3.8

(6)

 

 

Nozzle

 

 

Reduced

diameter

 

By-pass

 

flowrate

1/100

 

1/100 mm

 

(W)

mm

 

 

 

 

 

 

 

 

380

48

30 (1)

 

 

 

380

62

30 (1)

 

 

 

650

76

37 (2)

 

 

 

750

85

43

 

 

 

750

67

43 (3)

 

 

 

1200

87

55 (4)

 

 

 

380

48

30 (1)

 

 

 

92

 

55 (4)

1200

 

 

 

 

Flowrate

 

Flowrate

g/h G30

 

g/h G31

 

 

 

7675

120 118

185 182

225 222

145 143

240236

84 82

276 271

(1)= 33 for valveless appliances. (2)= 40 for valveless appliances. (3)= 45 for valveless appliances. (4)= 65 for valveless appliances.