Instructions for the installer

5.2 Regulation for LPG

Loosen screw A and push support B all the way. Use a double head wrench to remove nozzle C and assemble the suitable one, following the instructions indicated in the reference charts, with respect to the type of gas to use. The screwing torque of the nozzle should never exceed 3 Nm. Reposition support B so that nozzle C is covered perfectly.

Move the Venturi tube D to regulate the air flow until distance "X" is reached indicated in the chart in paragraph "5.4 Regulation of primary air” and then secure the tube by means of screw A. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.

 

 

Rated

 

 

Burner

 

heating

 

LPG – G30/G31 28/37 mbar

 

 

capacity

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

Nozzle

 

 

 

 

 

 

 

 

diameter

 

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (1)

 

 

 

1.05

 

48

 

 

 

 

 

 

 

 

 

 

Semi-rapid (2)

 

1.65

 

62

 

 

 

 

 

 

 

 

 

 

Rapid (3)

 

2.55

 

76

 

 

 

 

 

 

 

 

 

 

Rapid (4)

 

3.1

 

85

 

 

 

 

 

 

 

 

 

 

Ultra rapid (5)

 

3.9

 

95

 

By-pass

 

Reduced

 

Flowrate

 

Flowrate

 

 

 

 

 

mm

 

flowrate

 

g/h G30

 

g/h G31

 

1/100

 

(W)

 

 

 

 

 

30

33 (*)

380

76

75

30

33 (*)

380

120

118

37

40 (*)

650

185

182

43

45 (*)

750

225

222

 

65

1600

283

279

(*) By-pass value for valveless appliances.