Instructions for the installer
5 ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, disconnect the appliance from the electrical socket.
The hob has been inspected for LPG at a pressure of 30 mbar.
5.1Removing the separable control panel (models with separable control panel)
1.Remove the knobs and the knob guard tube “A” by pulling them up;
2.Use a crosshead screwdriver to remove the screws and the two cylindrical supports “B”;
3.Raise the
4.In models with electric hotplate, the body of the pilot light has to be removed to free the control panel;
5.Raise the ignition crosspiece “D” and rest it on the other side.
5.2Removing the hob (models with integrated control panel)
1.Remove the knobs, the griddles, the burner caps, the flame caps and the two rear plugs;
2.Remove the screws “A” which fix the burner supports;
3.Raise the hob, sliding it off the ignition plugs and/or the thermocouples and the gas tap rods;
4.Lift the ignition crosspiece and rest it on the other side.
11