5) ELECTRICAL CONNECTIONS

INSTALLATION

5) ELECTRICAL CONNECTIONS

The electrical connection must be made in conformity with current rules and regulations.

Before making a connection, check that:

-The capacity and outlets of the electrical installation are suitable for the maximum power output of the appliance (see the information label attached on the underside of the housing).

-The outlet or installation is provided with a good earth connection according to standards and provisions currently in force. All responsibility is declined for failure to comply with these provisions.

-If a power cord is not supplied with the appliance, connect a cable with a suitable section to the terminal board (see table in paragraph 6) keeping the earth wire longer than the lead wires, following the diagram in fig. 8.

When connection to the power circuit is made through an outlet:

-Apply to power cable "C", if not provided, a standard plug suitable for the load indicated on the information label. Connect the wires as in the diagram in fig. 8 taking care to observe the responses listed below:

Letter L (phase) = brown cable; Letter N (neutral) = blue cable;

Symbol ￿ (earth) = yellow-green cable.

-The power cord must be placed in a way that it does not reach an excess temperature of 75 K in any position.

-To connect, do not use adaptors or switches as they may cause false contacts resulting in dangerous overheating.

When connection is made directly to the power circuit:

-Place a switch between the appliance and the circuit of an appropriate size for the load of the appliance and with a minimum aperture between contacts of 3mm.

-Remember that the earth cable must not be broken by the switch.

-As an alternative, the electrical connection may also be protected by a high sensitivity differential switch.

It is strongly recommended that the yellow-green earth cable provided be connected to a good earth installation.

WARNING:

All of our appliances are designed and manufactured according to European standards EN 60 335-1 and EN 60 335-2-13 and relative amendments.

This appliance satisfies the requirements of European directives:

-CEE 89/336 + 92/31 + 93/68 concerning electromagnetic compatibility.

-CEE 73/23 + 93/68 concerning electrical safety.