Instructions for the installer
33
The hob has been inspected for G25 (2L3B/P) at a pressure of 25
mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.3 Regulation for LPG”, but
choose the nozzles and regulate the primary air for natural gas, as
shown in the following table and in paragraph “5.5 Regulation of
primary air”. After the regulations have been carried out, restore the
seals with sealing wax or equivalent material.
Burner
Rated
heating
capacity
Methaangas – G25 25 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W
Auxiliary 1.05 76 360
Semirapid 1.7 98 360
Rapid 2.55 120 650
Rapid large 3.3 132 750
Fish pan 2.9 126 950
Ultra rapid 4.1 150 1400