Instructions for the installer
26
The following operation requires building and/or carpentry work so
must be carried out by a competent tradesman.
Installation can be carried out on various materials such as masonry,
metal, solid wood or plastic laminated wood as long as they are heat
resistant (T 90°C).
2.1 Attachment to support structure
Create an opening with the dimensions shown in the figure in the top
surface of the counter, keeping a minimum distance of 50 mm from the
rear border.
This appliance is classified as “type Y” in relation to fire hazards and
can therefore be mounted against walls higher than the work surface
on condition that a certain distance “X” be kept between the appliance
and the wall as shown in the figure so as to avoid damage from
overheating.
Make sure there is a minimum of 750 mm between the hot plate flames
and any shelf that may be installed directly above them.
Accurately position the gasket provided all around the outer edge of the
hole in the top surface as shown in the figures below, pressing it down
so as to make it adhere properly. For measurements, refer to the figure
depending on the hob model to be installed, bearing in mind that in
both models the front and rear sides must skim the hole. Secure the
hob to the counter with brackets A or B(supplied). Carefully trim any
excess from border C of the gasket. The distances in the following
drawing refer to the hole on the inner side of the gasket.