17.FINAL OPERATIONS

Instructions for the installer

17.FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.

Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the appliance with the one corresponding to the new gas. This label is in the packet together with the nozzles.

17.1 Regulation of the hob burner minimum level for natural gas

Light the burner and turn it to the minimum position 17.3 Wall fixing. Extract the gas tap knob and turn the adjustment screw at the side of the tap rod until the correct minimum flame is achieved.

Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and to activate the safety device.

17.2 Mounting the rear top skirtboard (where applicable)

Loosen screws A located beneath the skirt.

Loosen nuts B.

Position the skirt above the top, taking care to align pins C with holes D.

Secure the skirt to the top by tightening screws E.

17.3 Wall fixing

Stretch out the chain attached to the cooker horizontally so that the other end touches the wall.

Mark the wall in the position where the hole is to be drilled.

Drill the hole, insert a wall plug and attach the chain.

Move the cooker up against the wall.

17.4 Positioning and levelling of the appliance

Having carried out the electricity and gas hook-up, level the appliance using the four adjustable legs. For best cooking the appliance must be perfectly level. Depending on the model you have purchased, the foot height adjustment range may vary from 70 to95 mm and from 110 to 160 mm. These heights refer to the distance between the highest point of thefoot (fixed part) and the lowest point (movable part which rests on the floor).