Smeg SUK81MFX5 manual Adaptation To Different Types Of Gas, Replacement of nozzles on the hob

Models: SUK81MBL5 SUK81MFA SUK81MFA5 SUK81MFX SUK81MFX5

1 20
Download 20 pages 18.55 Kb
Page 6
Image 6
3. ADAPTATION TO DIFFERENT TYPES OF GAS

Instructions for the installer

3. ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, disconnect the appliance from the mains.

The cooker hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of operation with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below.

3.1 Replacement of nozzles on the hob

This operation requires no primary air regulation.

1.Extract the grids and remove all the caps and flame-spreader crowns;

2.unscrew the burner nozzles with a 7 mm socket wrench;

3.replace the nozzles according to the type of gas to be used and the description in paragraph "3.2 Burner and nozzle characteristics table".

4.Replace the burners in the correct position.

8

Page 6
Image 6
Smeg SUK81MFX Adaptation To Different Types Of Gas, Replacement of nozzles on the hob, Instructions for the installer