| Integrated USB 2.0 Compatible |
|
|
| Datasheet |
| Table 4.1 | ||
|
|
|
|
NAME | SYMBOL | TYPE | FUNCTION |
|
|
|
|
|
| ||
|
|
|
|
USBDN[3:1] | These pins connect to the downstream USB peripheral | ||
Data | USBDP[3:1] |
| devices attached to the Hub’s ports. |
|
|
|
|
USB Power | PRTPWR[3:1] | O12 | Enables power to USB peripheral devices (downstream). |
Enable |
|
| The active signal level of the PRTPWR[3:1] pins are |
|
|
| |
|
|
| determined by the Power Polarity Strapping function of the |
|
|
| PRTPWR_POL pin. |
|
|
|
|
Port 3 Green LED | GR3/ | I/O12 | Green indicator LED for port 3. Will be active low when LED |
& | PRT_DIS0 |
| support is enabled via EEPROM or SMBus. |
Port Disable |
|
| If the hub is configured by the internal default configuration, |
strapping option. |
|
| |
|
| these pins will be sampled at RESET_N negation to | |
|
|
| |
|
|
| determine if port 3 will be permanently disabled. Also, the |
|
|
| active state of the LED will be determined as follows: |
|
|
| PRT_DIS0 = ‘0’, All ports are enabled, |
|
|
| GR3 is active high. |
|
|
| PRT_DIS0 = ‘1’, Port 3 is disabled, |
|
|
| GR3 is active low. |
|
|
|
|
Port [2:1] Green | GR[2:1]/ | I/O12 | Green indicator LED for ports 2 and 1. Will be active low |
LED | NON_REM[1:0] |
| when LED support is enabled via EEPROM or SMBus. |
& |
|
| If the hub is configured by the internal default configuration, |
Port Non- |
|
| |
|
| these pins will be sampled at RESET_N negation to | |
Removable |
|
| |
|
| determine if ports [3:1] contain permanently attached (non- | |
strapping option. |
|
| |
|
| removable) devices. Also, the active state of the LED’s will | |
|
|
| be determined as follows: |
|
|
| NON_REM[1:0] = ‘00’, All ports are removable, |
|
|
| GR2 is active high, |
|
|
| GR1 is active high. |
|
|
| NON_REM1:0] = ‘01’, Port 1 is |
|
|
| GR2 is active high, |
|
|
| GR1 is active low. |
|
|
| NON_REM[1:0] = ‘10’, Ports 1 & 2 are |
|
|
| GR2 is active low, |
|
|
| GR1 is active high. |
|
|
| NON_REM[1:0] = ‘11’, Ports 1, 2, & 3 are |
|
|
| GR2 is active low, |
|
|
| GR1 is active low. |
|
|
|
|
Gang Power | GANG_EN | I/O12 | If the hub is configured by the internal default configuration, |
Switching and |
|
| this pin will be sampled at RESET_N negation to determine |
Current Sensing |
|
| if downstream port power switching and current sensing are |
strapping option. |
|
| ganged, or individual |
|
|
| |
|
|
| ‘0’ = |
|
|
| ‘1’ = Ganged sensing & switching. |
|
|
|
|
Revision 2.3 | 10 | SMSC USB2503/USB2503A |
| DATASHEET |
|