Snapper 1667-0 Troubleshooting, Engine is running, but no AC or, DC output is available, Problem

Models: 1667-0

1 20
Download 20 pages 32.47 Kb
Page 12
Image 12
TROUBLESHOOTING

Snapper 3250 Watt Generator

TROUBLESHOOTING

Problem

Cause

Correction

 

 

 

 

 

 

1.

One of the circuit breakers is

1.

Reset circuit breaker.

 

 

open.

 

 

Engine is running, but no AC or

2.

Fault in generator.

2.

Contact Authorized service facility.

3.

Poor connection or defective cord

3.

Check and repair.

DC output is available.

 

set.

 

 

 

 

 

 

 

4.

Connected device is bad.

4.

Connect another device that is in

 

 

 

 

good condition.

 

 

 

 

 

Engine runs good at no-load but

1.

Short circuit in a connected load.

1.

Disconnect shorted electrical load.

 

 

 

 

"bogs down" when loads are

2.

Generator is overloaded.

2.

See "Don't Overload Generator".

connected.

3.

Shorted generator circuit.

3.

Contact Authorized service facility.

 

 

 

 

Engine will not start; or starts and

Low oil level.

Fill crankcase to proper level or place

runs rough.

 

 

generator on level surface.

 

 

 

 

 

 

1.

Out of gasoline.

1.

Fill fuel tank.

Engine shuts down when running.

2.

Low oil level.

2.

Fill crankcase to proper level or

 

 

 

 

place generator on level surface.

 

 

 

Engine lacks power.

Load is too high.

See "Don't Overload Generator".

 

 

 

 

 