Snapper 1693706 Normal Installation And Removal, Installation Instructions, 54”Turbo Blower

Models: 1695299 1693706

1 8
Download 8 pages 19.37 Kb
Page 8
Image 8
NORMAL INSTALLATION AND REMOVAL

Installation Instructions

54”Turbo Blower

NORMAL INSTALLATION AND REMOVAL

Installation

1.Insert the tapered spacers (B, Figure 11) through the bottom of the blower housing (A).

2.Install one spring clip (C) on each of tapered spacers

(B).

3.Hook the bottom of the turbo on the bottom hook bracket.

4.Use the release lever to release tension on the belt, and install the belt on the arbor pulley (see Figure 12).

5.Rotate the belt cover into position and secure with the plastic knob (D, Figure 11).

6.Install the spring (F). Connect the top of the spring to the bracket (E) and the bottom to the hole in the mower deck shell, just behind the discharge opening.

Installation WARNING

The deflector must be properly installed in the down position and retained by the spring. Do not operate the unit without a deflector.

 

E

 

F

A

 

 

C

C

B

 

 

D

B

 

Figure 11. Install Turbo

A.Turbo Blower Assy.

B.Tapered Spacers

C.Spring Clips

D.Plastic Knob

E.Bracket

F.Spring

Removal

1.Remove the spring (F, Figure 11).

2.Loosen the plastic knob (D, Figure 11).

3.Use the release lever to release tension on the belt, and remove the belt from the arbor pulley (Figure 12).

4.Remove the spring clips (C, Figure 11) from the tapered spacers (B).

5.Remove the turbo assembly (A) from the deck.

6.Close the small belt cover and secure with the plastic knob (D, Figure 11).

7.Return the deflector to the down position.

NOTE: The baffles (Figure 10) do not need to be removed.

FRONT

Figure 12. Install Turbo

MANUFACTURING, INC .

Form No. 1720927-06

500 N Spring Street / PO Box 997

Rev. 03/2007

© 2007 Briggs and Stratton, Inc. All Rights Reserved

Port Washington, WI 53074-0997 USA

TP 200-2325-06-AT-SMA

Page 8
Image 8
Snapper 1693706, 1695299 Normal Installation And Removal, Installation Instructions, 54”Turbo Blower