Pin Assignments 
 Pin #  Directio
n
Function 
1  IN  DCD — Carrier detect 
2  IN  RXD serial data from local host 
3  OUT  TXD serial data to local host 
4  OUT  DTR Data terminal ready 
5   Ground 
6  IN  DSR Data set ready 
7  OUT  RTS Request to send to local host 
8  IN  CTS Clear to send from local host 
9    Optional power input (3.3 to 5.0 Vdc) 
Power Mechanisms:  
The CSA operates from DC power and can be powered via one of two 
mechanisms: 
1. From the Pow er Jack on the CSA.  
When supplying DC power to the power jack, please note the following: 
• The acceptable supply voltage for normal operation ranges from 3.5 
to 5.5 VDC, with an Absolute Maximum is 5.6V. 
• The Power supply must rise to its final voltage in less than 1mS. 
• For specifications of the power jack’s physical connector, refer to 
SMK part number LGP3131-0111 at http://www.smk.co.jp. 
2. From Pin 9 of the DB-9 Connector.  
The acceptable supply voltage ranges from 3.5 to 12 VDC, with an 
Absolute Maximum of 12V.  
The CSA was not intended to be connected directly to a vehicle’s 
electrical system, although a cigarette lighter adapter/DC charger is 
permissible. 
The typical current requirements are provided in the table below. 
Note: The power supply should be capable of supplying a minimum of 
200 mA to ensure proper operation. 
Mode  Average  Max  Units 
Connected 40.5 76.5 mA 
Connected standby  
(RS-232 transceiver off) 3.5 53.0 mA 
Waiting to connect 39.1 55.9 mA 
Waiting to connect standby  
(RS-232 transceiver off) 2.3 19.1 mA 
APPENDIX A: SPECIFICATIONS  35