Confirm the message "General" by pressing ENTER.

• Exit Setting mode by pressing the ORG key. The

Press the TARE key to browse to "Fixed tare va-

gross value is displayed.

 

lues" and accept by pressing ENTER.

 

 

 

Using the dialysis function

Clearing a tare value

The last selected fixed tare value memory is displayed. Press the F or TARE key to browse the required fixed tare value memory or enter the memory location number and confirm by pressing ENTER.

Clear the displayed fixed tare value memory by pressing the C key.

The gap in the consecutive number scheme is closed. The following fixed tare value memories are given a number reduced by 1.

Press the F key (with a load on the scale). Mes- sage: "Place tare". Place the additional tare on the scale. Confirm by pressing TARE. The addi- tional tare is accepted into the tare memory and the net value remains unchanged.

Repeat this procedure for other additional tares. The weight is displayed with the message "Net". When the scale is clipped off, the tare weight is displayed with a negative sign.

Clear the tare by pressing the ZEROING key.

CAUTION: Under Setting mode > Program Set- tings > General > Delete fixed tare values, all fixed values are cleared from the memory!

Provisional tare/dialysis function

Setting and using the operating mode

Setting in Setting mode

(Setting mode > Program Settings > Weig- hing + Taring > F key > Dialysis function)

Press ENTER and the F key simultaneously to access Setting mode.

The arrow points to "Program Settings". Press ENTER to confirm.

Press TARE to browse down to "Weighing + Ta- ring" and press ENTER to confirm.

Confirm the message "F key" by pressing ENTER.

Press TARE (down) or the F key (up) to browse to "Dialysis function" and press ENTER to confirm. There is an acoustic acknowledgement.

Displaying the value in the tare memory

To display the tare memory, press the INFO key and then the TARE key. Press the ZEROING key to exit the display.

Changing the tare value manually later

Display the tare value by pressing the INFO key and then the TARE key. Enter the new value into the KEYPAD. Press the ZEROING key to abort the input. The existing value is retained or the new tare value is saved by pressing the TARE key. Confirm by pres- sing ENTER and return to the application program.