Soehnle 7731, 7730 user manual Faults Causes and Remedies, Display Causes Remedy

Models: 7731 7730

1 32
Download 32 pages 24.31 Kb
Page 19
Image 19

3. FAULTS – CAUSES AND REMEDIES

DISPLAY

CAUSES

REMEDY

 

 

 

 

The scale is not reset to »0.0 kg« when

Unload the scale and restart the

 

switched on.

display unit. If the error remains,

 

 

please contact your service partner.

 

 

 

 

Underload: only dashes appear at the bottom

Switch the display off and on again,

 

of the display field.

or pull out the mains plug. If the error

 

 

occurs again, please contact your

 

 

service partner.

 

 

 

 

Overload: only dashes appear at the top of

Unload the scale, or switch them off

 

the display field. Maximum weighing range is

and on again. Check the maximum

 

exceeded.

weighing range.

 

 

 

 

The weighing value does not stabilise.

Check the surface under the scale,

 

 

and check that the weighing platform

 

 

is level. If the error persists after

 

 

readjustment, please contact your

 

 

service partner.

 

 

 

 

The weighing value does not stabilise.

Stand still or stabilise the weight on

 

 

the scale or restart the scale.

 

 

 

 

Height rod is not in reference position during

Fold up the height rod during power-

 

power-up

up.

 

 

 

 

The rechargeable battery is empty.

Charge the battery.

 

 

 

If the fault cannot be cleared, or other error messages appear, please contact your service partner.

19

www.soehnle-professional.com

Page 19
Image 19