Soleus Air GH-PAC-12E1HP WITH HEAT Troubleshooting, Problem, Possible Causes, Solutions

Models: GH-PAC-12E1 GH-PAC-12E1HP WITH HEAT

1 16
Download 16 pages 38.58 Kb
Page 14
Image 14
TROUBLESHOOTING

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSES

SOLUTIONS

 

 

 

The Air Conditioner will not start

The air conditioner is unplugged or not

Make sure the air conditioner plug

 

connected well.

is pushed completely into the out-

 

 

let

The fuse is blown/circuit breaker is tripped.

Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.

The unit will automatically re-start

Power Failurewhen power is restored.

There is a protective time delay (approx. 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.

The current interrupter device is tripped.

Press the RESET button located on the power cord plug.

If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

The Air Conditioner does not cool as it should

The Dehumidifier function is not providing cool air as it should

The Air Conditioner displays the Timer hours but does not work

Airflow is restricted

Make sure there are no curtains,

 

blinds, or furniture blocking the

 

front of the air conditioner

 

 

The temperature control may not be

Lower the set thermostat tempera-

set correctly.

ture

 

 

The air filter is dirty

Clean the filter. See the Cleaning

 

and Care Section of the manual.

 

 

The room may be too warm

Please allow time for the room to

 

cool down after turning on the air

 

conditioner.

 

 

Cold air is escaping

Check for open furnace registers

 

and cold air returns

 

 

The Evaporator is frozen

The unit is defrosting and will re-

 

sume operation when done.

Is the TIMER ON enabled?

Cancel the TIMER or wait until the

 

unit turns on.

The Remote Control is not working The batteries are inserted incorrectly The batteries may be dead

Check the position of the batteries.

Replace the batteries