USING YOUR AIR CONDITIONER (Cont.)

Freezing Conditions: This is a cooling only air conditioner. It is not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions.

Remote Control: To ensure proper operation when using the remote control, aim the remote directly at the signal receiver on the air condi- tioner.

The remote control has a signal range up to 20 feet.

Make sure nothing is blocking the remote con- trol signal from being received by the air con- ditioner.

Make sure the batteries are installed correctly and still have power.

Cooling Mode: Use the COOL mode at Low, Me- dium, High, or Auto Fan speed when cooling is needed. Use the temperature ▲/▼ buttons to set the desired temperature between 64°F and 86°F.

Once the temperature is set, the compressor will cycle on and off to keep the room temperature at the set temperature level. The lower the set thermostat temperature, the cooler the room will become. The higher the set thermostat temperature, the warmer the room will become.

For Normal Cooling - Set the Mode to Cool and the Fan to High or Med with the termperature set in the middle.

For Maximum Cooling - Set the Mode to Cool and the Fan to High with a lower set temperature.

For Quieter & Nighttime Cooling - Set the Mode to Cool and the Fan to Low with the temperature set in the middle.

NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.

Energy Saver Mode - Controls the Fan

Fan Only Mode: Use Fan Only mode at Low, Med, or High fan speed to provide air circulation and filtering without cooling. Since fan only setting do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.

NOTE: Auto Fan Speed cannot be used in Fan Only mode.

Loss of Power Protection: If power to the air conditioner is lost or interrupted, the air condi- tioner will automatically re-start in the setting last used prior to power loss. If the Timer was set to automatically turn the air conditioner off or on, it will resume countdown at the amount time left prior to power loss. You may need to set a new time if desired.

Air Direction: Use the lever on the front air vents to adjust the direction of the airflow. You can di- rect the airflow left, right, up or down. The lever is located on the right side of the air vent.

On - The fan will cycle on and off with the compressor. This results in winder variations of room temperature and humidity. Normally used with the room is unoccupied. NOTE: The fan may continue to run for a short time after the compressor cycles off.

Off - The fan runs all the time in fan or cooling mode.

13

Page 14
Image 14
Soleus Air GM-WAC-06ESE-C, GM-WAC-06SE-C, GM-WAC-08ESE-C manual Using Your AIR Conditioner

GM-WAC-06ESE-C, GM-WAC-08ESE-C, GM-WAC-06SE-C specifications

The Soleus Air GM-WAC-06SE-C, GM-WAC-08ESE-C, and GM-WAC-06ESE-C are compact and efficient window air conditioning units designed to deliver powerful cooling while maintaining energy efficiency. Ideal for small to medium-sized rooms, these units offer an impressive blend of features, making them suitable for a variety of residential applications.

One of the standout features of these models is their Energy Efficiency Ratio (EER) ratings, which are quite high. This means that they consume less energy while still providing effective cooling, helping users save on electricity bills. The GM-WAC-06SE-C and GM-WAC-06ESE-C both feature a 6,000 BTU cooling capacity, while the GM-WAC-08ESE-C boasts an 8,000 BTU capacity, making it more capable for larger spaces.

The units come equipped with adjustable fan speeds, allowing users to customize their cooling experience. With multiple fan speeds, users can choose between high, medium, and low settings to suit their comfort needs. The noise level is impressively low for a window air conditioner, ensuring that the environment remains peaceful while the unit operates.

Soleus Air ensures user convenience by incorporating an easy-to-use remote control with these models. The remote allows users to adjust settings from a distance, making it simple to switch modes, set the thermostat, or change fan speeds. Additionally, these units feature a programmable timer, which enables users to set the air conditioner to automatically turn on or off at designated times, further enhancing energy savings.

The self-evaporative system is another significant feature of these models. It eliminates the need for continuous manual draining. Instead, the condensation collected during the cooling process is expelled outside, reducing maintenance requirements and improving user experience.

The design of the Soleus Air window units emphasizes a sleek and modern appearance, making them visually appealing in any room setup. The air conditioners are also equipped with a washable and reusable filter, ensuring that the air remains clean and fresh by effectively capturing dust and allergens.

In summary, the Soleus Air GM-WAC-06SE-C, GM-WAC-08ESE-C, and GM-WAC-06ESE-C offer a smart combination of efficiency, adjustable features, and user-friendly technologies. Ideal for residential cooling needs, they stand as an excellent choice for those seeking reliable and effective air conditioning solutions while keeping energy consumption in check.