Soleus Air KFMHP-24-OD manual Model, KFMHP-18-ID, KFMHP-24-ID, KFMHP-18-OD

Models: KFMHP-18-ID KFMHP-18-OD KFMHP-24-ID KFMHP-24-OD

1 29
Download 29 pages 38.62 Kb
Page 28
Image 28
Model

Power Supply (Ph-V-Hz)

Breaker Size (A)

Cooling

Heating

Indoor

outdoor

Lines Sets

Model

KFMHP-18-ID

KFMHP-24-ID

KFMHP-18-OD

KFMHP-24-OD

 

 

1/230/60

1/230/60

 

20

20

Rated Capacity (BTU)

18,000

23,000

 

Capacity Inverter Range(Wattage)

5,000(2,000-6,800)

6.400(3,000-8,500)

 

Input/Actual Input(Wattage)

1385/1450

1830/1882

 

Max.Power (Wattage)

2450

3000

 

Max.Current(Amperage)

11

13

 

Declared EER/Actual EER

12.3/11.8

11.9/11.6

 

SEER

15.6

14.2

 

Rated Capacity (BTU)

21,000

26,000

 

HSPF

7.7

7.7

 

Capacity Inverter Range(Wattage)

2,800-7,000

2,800-8,000

 

Max.Power (Wattage)

2,580

3,200

 

Max.Current(Amperage)

11.5

13.5

 

Input/Actual Input(Wattage)

1,550/1,580

2,000/2,060

 

Declared COP/Actual COP (w/w.h)

3.75/3.65

3.5/3.4

CFM (H/M/L)

324/306/194

441/406/217

 

Noise Level dB (A)

41

43

 

Indoor Unit Tubing Diameters(Inch)

0.28x0.25

0.28x0.25

Indoor Unit Core

16.46-3F

16.46-3F

Indoor Unit Dimension (W*D*H)

34.3"X7.1"X10.6"

40.2"X13.8"X10.8"

 

Indoor Packing Dimension (W*D*H)

35"X8.1"X11.3"

41"X14.5"X11.3"

 

Indoor Net/Gross Weight (Lb)

26/31

31/35

Design Pressure(PSIG)

510

510

Outdoor Unit Dimension (W*D*H)

39"X16.1"X30.7"

41.7"X18.5"X36.4"

 

Outdoor Packing Dimension (W*D*H)

40"X17"X31.2"

42.4"X19"X37"

 

Outdoor Net/Gross Weight (Lb)

128/143

163/181

 

Design Pressure(PSIG)

510

510

Noise Level dB (A)

57

57

 

Outdoor Unit Core

S3P

NSP

Line Set Size(Inch)

1/4,3/8

1/4,1/2

 

Refrigerant Type (lbs)

R410A/3.9lbs

R410A/6.6lbs

 

Max. Length [Ft]

82

82

 

Max.Vertical Separate(Ft)

32.8

32.8

 

Factory Charge(Ft)

16.4

16.4

 

Add Charge(Lbs/Ft)

0.01

0.01

 

Page 28