CONDENSATE WATER DRAINAGE
1)Internal Water Tank
When operating in cooling or dehumidifying mode, the condensate water will drain into the internal water tank. Depending on the surrounding humidity, the unit can continu- ously operate for 2 to 12 hours before the internal water tank is full. When the internal water tank gets full, a beep slarm will sound eight times for 15 seconds. The compres- sor stops running and the fan will continue to run in the set speed for three minutes before the entire unit automatically shuts off.
When the water tank is full, take out the entire water tank slowly and discard the water inside the tank, place it back to its original position. You will then be able to turn on the unit again.
If you want to take out the internal tank before it is full of water, please stop the unit first. Wait for 3 minutes before taking out the water tank to prevent the condensate water from discharging into the unit.
NOTE: Do not take out the water tank when the unit is running on either cooling or dehumidi- fying mode or the alarm will sound and the compressor stops. The mode will automatically change to FAN mode and the compressor will require approximately 3 minutes to restart to the cooling/dehumidifying cycle.
9
66126113.p65 | 9 |