CONDENSATE EVAPORATION

CONDENSATE EVAPORATION

Emergency Condensate Holding Tank

When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automatically shut off and the led of BUCKET FULL will light up on the control panel display. To empty the condensate tank, pull the drain plug at the bottom back of the unit. You will need a small pan, approximately 1” high to catch the water coming out of the condensate tank. Connect the supplied drainage hose to the back of the unit to aid in drainage into the pan. Once the condensate tank is drained, the unit will begin working within a few minutes. The emergency condensate tank is approximately 1.5 Liters of water. Another option is to purchase a small hose from a hardware store that can fit around the 5/8” drain plug on the back of the unit and drain the unit into a gravity drain or larger pan for continuous drainage. It is not advised to use continuous drain-

age when the room temperature is higher than 90°F .

If you do not need the emergency tank emptied immediately simply leave the unit on. The fan in your air conditioner will continue to run to help evaporate the moisture as fast as possible. This will usually take around 60 minutes depending on how much water is in the tank.

To resume operation quickly, empty the water container according to the following steps:

1.Turn the unit off. Do not move the unit when the water container is full.

2.Place the drain pan accessory under the drainage port at the back of the unit.

3.Remove the rubber plug from the drain hole. The condensate water will drain out automatically.

4.When the drain pan is full, install the rubber plug back onto the drainage hole to stop the water flow.

5.Empty the drain pan.

6.Repeat steps 2-5 until all the water is emptied.

NOTE: Once the water container has been emptied, install the rubber plug back onto the drain hole. It is not advised to use continuous drainage when the room temperature is higher than 90°F .

11

Page 11
Image 11
Soleus Air PE8-12R-32 manual Condensate Evaporation, Emergency Condensate Holding Tank

FAQ

What should I do if the BUCKET FULL LED on my air conditioner's control panel lights up?

To empty the condensate tank, pull the drain plug at the bottom back of the unit and use a small pan to catch the water.

Can I use continuous drainage for the condensate tank?

Yes, you can purchase a small hose to drain the unit into a gravity drain or a larger pan for continuous drainage, but it is not advised when the room temperature is higher than 90F.

How long does it take for the air conditioner to evaporate the moisture in the emergency condensate tank?

It usually takes around 60 minutes depending on how much water is in the tank.