ELECTRICAL REQUIREMENTS

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove the ground prong. Do not use an adapter

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock

Recommended Ground Method

The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front).

Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord.

Wiring Requirements

Power Supply Cord

 

 

115 volt (103.5 min.—126.5 max)

0-12 amps

15-amp time-delay fuse or circuit breaker

Use on single outlet circuit only

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the cus- tomer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.

It is the customer’s responsibility:

To contact a qualified electrician

To assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances.

Copies of the standards listed may be obtained from: National Fire Protection Association

One Batterymarch Park

Quincy, Massachusetts 02269

LCDI Power Cord and Plug

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.

The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de- energized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test the plug:

1.Plug power cord into a wall outlet

2.Press the TEST Button, the circuit should trip and cut all power to the air conditioner

3.Press the RESET button for use

If a test is performed and the indicator light remains ON, the current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Customer Service for troubleshooting recommendations.

3

Page 3
Image 3
Soleus Air SG-WAC-05SM Electrical Requirements, Recommended Ground Method, It is the customer’s responsibility

SG-WAC-05SM specifications

The Soleus Air SG-WAC-05SM is a versatile and efficient air conditioning unit, designed to provide optimal comfort while remaining energy efficient. This window air conditioner is perfect for small to medium-sized rooms, making it an ideal choice for apartments, bedrooms, or home offices.

One of the key features of the SG-WAC-05SM is its cooling capacity of 5,000 BTUs, which enables it to cool rooms of up to 150 square feet with ease. The unit incorporates a user-friendly control panel with intuitive options, allowing you to customize your cooling experience. It comes equipped with multiple cooling and fan speeds, ensuring that you can find the perfect setting to suit your preferences and the temperature of your environment.

The air conditioner also features a programmable thermostat, allowing for precise temperature control. This helps to enhance comfort while also contributing to energy savings, as you can set the unit to cool your space only when needed. The SG-WAC-05SM includes an energy saver mode, which automatically turns off the compressor once the desired temperature is reached, reducing energy consumption and lowering electricity bills.

Soleus Air has integrated advanced technologies in the SG-WAC-05SM to improve air quality and provide additional functionality. The unit includes a washable and reusable air filter that helps to capture dust and pollutants, promoting cleaner air in your living environment. Regular maintenance is straightforward, and the filter can be easily accessed and cleaned.

In terms of noise level, the SG-WAC-05SM is relatively quiet, operating at a sound level that ensures minimal disturbance while it cools your space. Additionally, the unit's design allows for efficient installation in most standard window frames, providing flexibility for various living situations.

The sleek design and compact size of the Soleus Air SG-WAC-05SM fit seamlessly into any room décor, making it an appealing addition to your home. Whether you're seeking relief from the summer heat or simply aiming to maintain a comfortable indoor atmosphere, the Soleus Air SG-WAC-05SM is a reliable and efficient choice that combines functionality, technology, and convenience.