USING YOUR AIR CONDITIONER (Cont.)

Freezing Conditions: This is a cooling only air conditioner. It is not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions.

Remote Control: To ensure proper operation when using the remote control, aim the remote directly at the signal receiver on the air condi- tioner.

The remote control has a signal range up to 20 feet.

Make sure nothing is blocking the remote con- trol signal from being received by the air con- ditioner.

Make sure the batteries are installed correctly and still have power.

Cooling Mode: Use the COOL mode at Low, Me- dium, High, or Auto Fan speed when cooling is needed. Use the temperature ▲/▼ buttons to set the desired temperature between 64°F and 86°F.

Once the temperature is set, the compressor will cycle on and off to keep the room temperature at the set temperature level. The lower the set thermostat temperature, the cooler the room will become. The higher the set thermostat temperature, the warmer the room will become.

For Normal Cooling - Set the Mode to Cool and the Fan to High or Med with the termperature set in the middle.

For Maximum Cooling - Set the Mode to Cool and the Fan to High with a lower set temperature.

For Quieter & Nighttime Cooling - Set the Mode to Cool and the Fan to Low with the temperature set in the middle.

NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.

Energy Saver Mode - Controls the Fan

Fan Only Mode: Use Fan Only mode at Low, Med, or High fan speed to provide air circulation and filtering without cooling. Since fan only setting do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.

NOTE: Auto Fan Speed cannot be used in Fan Only mode.

Loss of Power Protection: If power to the air conditioner is lost or interrupted, the air condi- tioner will automatically re-start in the setting last used prior to power loss. If the Timer was set to automatically turn the air conditioner off or on, it will resume countdown at the amount time left prior to power loss. You may need to set a new time if desired.

Air Direction: Use the lever on the front air vents to adjust the direction of the airflow. You can di- rect the airflow left, right, up or down. The lever is located on the right side of the air vent.

On - The fan will cycle on and off with the compressor. This results in winder variations of room temperature and humidity. Normally used with the room is unoccupied. NOTE: The fan my continue to run for a short time after the compressor cycles off.

Off - The fan runs all the time in fan or cooling mode.

13

Page 13
Image 13
Soleus Air SG-WAC-10ESE-F, SG-WAC-12ESE-F manual Using Your AIR Conditioner

SG-WAC-10ESE-F, SG-WAC-12ESE-F specifications

The Soleus Air SG-WAC-12ESE-F and SG-WAC-10ESE-F are two standout window air conditioning units designed to provide effective cooling and comfort in residential spaces. Known for their innovative features and advanced technologies, these models cater to diverse cooling needs while maintaining energy efficiency.

One of the primary features of both models is their powerful cooling capacity. The SG-WAC-12ESE-F offers a cooling capacity of 12,000 BTUs, making it ideal for larger rooms up to 450 square feet. In contrast, the SG-WAC-10ESE-F provides a slightly lower capacity of 10,000 BTUs, suitable for spaces around 350 square feet. This range of capacities ensures efficient cooling solutions for various room sizes.

Energy efficiency is a key characteristic of these units. Both the SG-WAC-12ESE-F and SG-WAC-10ESE-F come with high Energy Efficiency Ratios (EER), which helps customers save on electricity bills while maintaining a comfortable indoor environment. They are designed with eco-friendly refrigerants, further decreasing their environmental impact.

Another highlight of these models is their multi-functionality. They feature not only cooling modes but also fan-only and dehumidification modes. This versatility allows users to select the best operation mode based on their needs, particularly during milder weather conditions when full cooling isn't necessary.

The units are equipped with user-friendly digital controls and a remote that allows for convenience and ease of use. The programmable timer feature enables customers to pre-set operation schedules, ensuring that the room is at the desired temperature when they arrive home. Additionally, the units come with adjustable air louvers that direct airflow where it is needed most, improving cooling efficiency.

Noise levels are also a significant consideration, and these models have been engineered to operate quietly. Their reduced operational noise ensures minimal disturbance, making them suitable for bedrooms, offices, or other quiet spaces.

Installation of the Soleus Air SG-WAC-12ESE-F and SG-WAC-10ESE-F is simplified with a user-friendly design that facilitates easy mounting in standard windows. Their durable construction and sleek appearance also blend seamlessly with various home aesthetics.

In summary, the Soleus Air SG-WAC-12ESE-F and SG-WAC-10ESE-F are efficient, powerful, and versatile window air conditioning units that meet the cooling needs of different room sizes. With energy-saving features, user-friendly controls, and quiet operation, they are excellent choices for anyone looking to enhance indoor comfort.